PLS-601 Programmable Limit Switch

Blow-off & Part Lubrication Programmable Limit Switch

PLS-601 - Full Featured Programmable Limit Switch

A programmable limit switch is a device which overcomes the shortcomings of mechanical cam switches by performing the cam functions electronically rather than mechanically. Instead of having to physically adjust the timing and dwell of a number of mechanical cams, the programmable limit switch (PLS) allows a user to enter the timing and dwell settings via a keyboard. The timing and dwell settings are then stored in a solid state memory and used to control whether the outputs of the electronic switches are turned ON or OFF.

The PLS-601 provides one source for all of your programmable limit switch actions at your machine. It is used to control automated functions during a machine cycle. This product will eliminate the time it takes to manually adjust mechanical limit switches.

The front panel utilizes an alpha numeric display, 3-mode keyswitch and keyboard. Status LEDs for channel output and motion detect, combined with other features, gives this product unparalleled functionality.



Features

  Standard Option
Programmable limit switches  
Eight output channels  
Expandable to 64 outputs  
Tachometer & Motion detector  
Fast scan time & High noise immunity  
Simple setup and operator use  
16-digit vacuum fluorescent display  
Simultaneously displays information  
Brushless resolver  
Multiple setpoints for each output  
EEPROM memory  
Internal DC power supply  
Plug-type connectors  
Key lock security protection  
Fault check circuitry  
Single-turn or multi-turn  
Standard bus or auxiliary output  
Up to 50 job storage  
Brake monitor  
Timed dwell  
Speed compensation  
Flushmount kit  
Nema enclosure  

Specifications

  General Specifications
Input Power 115VAC +/- 10%, single phase, 50/60 Hz
Operating Temperature 32-125 degrees Fahrenheit
Storage Temperature 0-180 degrees Fahrenheit
Maximum Resolution 1000 counts/turn
Standard Scan Time 200 microseconds
300 rpm @1000 counts per turn
Display .1 line x 16 characters LCD
Maximum Number Of Lobes 3808 Total
(238 lobes x program x group = 238 x 4 x 4)

  Resolver Specifications
Input Voltage 7.0 Vrms
Input Frequency 5000 Hz
Primary Winding Rotor (R1,R2)
Input Rotor Current (max) 10.9 mA
Input Power 47 mW
Output Voltage (stator windings) 6.7 Vrms
Transfer Ratio .95
Phase Shift (open circuit) Leading -6 Degrees
Sensitivity 116 mV/deg.
DC Rotor Resistance 16 ohms +/- 10% ohms
DC Stator Resistance 52 ohms +/- 10% ohms
Total Null Voltage 15 mV
Accuracy Maximum Error +/-7 Minutes

  Width Height Depth
Dimensions 7.00 " 4.75 " 5.75 "

Manual/Downloads

Name Format Link
User Manual PDF

Accessories/Related

Type Name Description Link
Standard Product TR-1 Resolver Single Turn Resolver
Service Installation On-site product installation

Contact