Ram-Read / Ram-Rod - Shut Height Display
The RAM-READ and RAM-ROD is a shut-height system that shows ram position during die changeover.
Create a faster setup time, decrease die hit-to-hit and reduce downtime using a repeatable shut-height
value with a positioning accuracy of +/- .001 inch.
The Ram-Read/Ram-Rod can be interfaced to a PLC or our automation packages.
The shut-height value can be displayed on these systems operator interfaces, eliminating the need
for the Ram-Read and making it a cost effective upgrade. Also, when it is used with a production
monitor or automation package, shut-height, tonnage, etc. decreases setup time even more!
Features
| Standard | Option | |
| Digital input for run/program switch | ![]() |
|
| Six/seven segment, large display | ![]() |
|
| Password protected | ![]() |
|
| Programmable zero offset | ![]() |
|
| Programmable bolster offset | ![]() |
|
| Programmable position "hold" | ![]() |
|
| Reads out in inches or millimeters | ![]() |
|
| Programmable negative overshoot | ![]() |
|
| Programmable movement detection | ![]() |
|
| Upper and lower control limits | ![]() |
|
| Interfaces with N260, Maximizer and Co-Pilot |
![]() |
Specifications
| RS-485/232 Output |
115.2K baud |
| Environmental | Humidity: 5% to 95%; Non-condensing |
| Temperature | Operating: 32° to 131° F; Storage: 0° to 150° F |
| Power Requirements |
85-265 VAC 50/60Hz; Internally Fused at 1.5 Amps |
| Memory Retention Time |
Saves last programmed values for ten years without power |
| Movement Input | 85-265 VAC, 12mA (rms) maximum; Optical isolated to 3200 VDC/2250 VAC |
| Program Mode Key Input |
Dry Contact; Open Collector (drain) only; +5 VDC maximum - Current 0.2mA |
| Relay Contact Ratings |
All relays rated UL & CSA for ¼ HP, 125 to 250 VAC;
8A 250 VAC, 30 VDC, Shock Resistant to 10G |
| Shock & Vibration | Tested to: MIL-STD 810E, Method 514.4, Category 10, 20-2K Hz,
2G sine, 0.04 G² Hz random, UL 491, SA 19, 10-150 Hz, 10 G sine |
| Electromagnetic Compatibility |
Tested to: IEC 801-2, Level 5 (Electrostatic discharge requirements);
IEC 801-4, Level 4 (Electrical fast transient/burst requirements); IEC 801-5, Level 3.5 (Surge immunity requirements) |