SLIM - Resolver Based Signature Force Monitor
The SLIM is a resolver-based tonnage signature interface module that provides force measurement and signature
analysis for critical force applications up to 800 spm. The SLIM unit is designed and configurable for
single action, double action and transfer presses.
Signature analysis can be used in determining the amount
of force exerted throughout the press stroke. This can be especially useful in determining if
the amount of stress on the press is happening too early in the stroke. It is important to know what tonnage is being
developed and where in the press stroke it occurs.
Every press manufacturer provides a
press rated tonnage curve and motion diagram, which can be uploaded into our SLIM monitor. This curve is then plotted against the
actual tonnage signature and can be viewed through the user interface software, SlimWare.
4-Channel Signature with Critical Curve Monitoring and Enveloping
The SLIM's onboard memory allows for operators/setup personnel to retrieve the last 25 signatures.
Along with signatures, setpoints can be saved and loaded with each job. These setpoints include:
- Capacity
- CCM (Critical Curve Monitoring)
- High Setpoint
- Low Setpoint
- High Enveloping (5-Zones)
- Low Enveloping (5-Zones)
- Reverse Setpoint
Each of the alarm types listed above can be set as a top or immediate stop within the SLIM. Each channel (corner)
can be enabled or disabled as well (with a master password). The SLIM also provides basic statistics such as:
- Highest Load
- Lowest Load
- Last Alarm
- Last High Alarm
- Last Low Alarm
- Number of Capacity Alarms
- Number of CCM Alarms
- Number of High Alarms
- Number of Low Alarms
- Number of Reverse Alarms
The SLIM can also interface with a wide variety of equipment ranging
from the most sophisticated Allen-Bradley & Siemens programmable logic controllers (PLCs)
through the use of OPC server/client tags, to standard personal computers (PCs) through the use of starndard
text files.
The SLIM unit also provides a starndard option of data-logging. This option saves any alarm, setpoint or configuration change
to a text file along with a timestamp and user ID. This can provide a detailed history of any alarms or changes made to the
SLIM unit.
For a more detailed alarm history, our PressNet and MaxNet networking packages allow for detailed reporting
by time, press, user and types of alarms. To view more about our networking
packages, click here.
The SLIM unit comes standard with the user interface software, SlimWare. This software can be installed on any
desktop/industrial PC with the following operating systems:
- Microsoft Windows 2000
- Microsoft Windows XP
- Microsoft Windows XP Embedded
- Microsoft Windows Vista
- Microsoft Windows 7
Sample SlimWare screenshots are shown below:
Tonnage

Tonnage Alarm

Signature

Setpoints

Features
Standard | Option | |
Signature load module for strain gage sensors and load cells |
![]() |
|
Up to eight analog channels for accommodating up to sixteen sensors |
![]() |
|
Generates signatures and enveloping with one degree resolution |
![]() |
|
CCM - Critical Curve Monitoring | ![]() |
|
Press shutdown relay for alarm condition | ![]() |
|
Triggered by resolver, internal threshold setting or threshold probe |
![]() |
|
LED indicators for serial data and threshold probe activities |
![]() |
|
Digital balance and gain setup | ![]() |
|
Steel enclosure for maximum protection and noise rejection |
![]() |
|
Fully compatible with PressNet and MaxNet networking software |
![]() |
|
Terminals for external alarm reset switch connection |
![]() |
|
Compact design for flexible system integration and re-configuration |
![]() |
|
Built-in power supply for stable operation and noise rejection |
![]() |
|
Expandable design allows interface with optional I/O module |
![]() |
|
Interface with the Maximizer or Maximizer TPC |
![]() |
|
Interface with HMI or PLC (job and mode sharing) |
![]() |
|
Analog output terminals | ![]() |
|
RS-485/232 serial ports for interfacing | ![]() |
|
SlimWare user interface | ![]() |
|
Automatic Zero Balance | ![]() |
Specifications
No. Of Channels | Two,Four,Six or Eight |
Sensor Inputs | Full bridge strain gauge sensors 120 to 1000 ohms Up to (16) 350 ohm sensors |
Sensor Excitation | Built-in 10VDC @ 500mA max (Short circuit protected) |
Sensor Input Connections |
7-pin .2" pitch Phoenix connector |
Auto-Zero Time Constant |
N/A |
Balance Range | +/- 1mV/V of offset |
Gain Range | 100-11,000x (digitally controlled) |
Analog Output | 1.25VDC @ Press Capacity |
Analog Output Connection |
11-pin .15" pitch Phoenix connector |
Peak Delay | N/A |
Accuracy | +/- 1% of full scale max |
Non-linearity | +/- .1% of full scale max |
Frequency Response |
Flat DC to 6KHz |
Resolution | Each channel provides a 4-digit load value in 1024 count resolution |
SPM | 800 SPM (resolver trigger) |
Calibration Shunts | Calculation based on 1 Meg Ohm shunt resistor |
Computer Interface |
(3) RS-232/422 serial ports (38.4K - 460K baud) |
Trigger | Resolver, Probe or Threshold |
Thershold Probe | Built-in voltage source (12VDC @ 80mA max) provides power for NPN or PNP proximity probes. Also supports limit switch, solid state or mechanical relays |
Resolver Interface | Built-in excitation supports standard 5000Hz rotor excited positional resolver |
Shutdown Relay | 8A @ 250VAC or 30VDC N.O. Contact (N.C. Optional) Bypass switch available |
Power Req. | 29 Watts max, 85-132VAC @ 50-60Hz OR 170-264VAC @ 50-60Hz (Use .25" x 1.25" SLO-BLO fuse) |
Expansion | Interface port for I/O module |
Operating Temp. | 0-70 degrees Celsius |
Weight | Approximately 22.3lbs |
Width | Height | Depth | |
Dimensions | 2.125 " | 12.0 " | 5.0 " |
Manual/Downloads
Name | Format | Link |
User Manual (Rev1 Board) | ![]() |
|
User Manual (Rev2 Board) | ![]() |
|
SlimWare V5 Demo | EXE | ![]() |