DPPlus Basic Automation Controller
The Toledo DPPlus unit is a basic press automation and control system that integrates die protection, programmable
limit switches, brake monitoring and job storage into an encoder-based package. The DPPLUS unit itself is a "loose"
package and is designed for mounting in a NEMA rated enclosure or a panel.
The DPPlus comes standard with 4 die protection inputs, 8 programmable limit switch
outputs, brake monitor, parts and batch counters, separate immediate stop and top stop
outputs and configurable message inputs. The DPPlus has the capability to store
information for 50 jobs.
The DPPlus automation package is designed for basic automation needs such as die protection, programmable limit
switches and brake monitoring. This basic automation package includes a clutch/brake controller, the
Press Pilot 150.
To read more about the DPPlus basic automation package,
click here or contact us directly at 1-800-TTOLEDO.
Features
Standard | Option | |
4 die protection | ![]() |
|
Die protection input diagnostics | ![]() |
|
8 Programmable limit Switches | ![]() |
|
Mechanical PLS relays | ![]() |
|
Batch, part & stroke counters | ![]() |
|
Up to 50 job storage / recipes | ![]() |
|
Speed compensation | ![]() |
|
Time based brake monitor | ![]() |
|
90 degree stop test | ![]() |
|
Encoder based | ![]() |
|
Motion detection | ![]() |
|
2 password levels | ![]() |
|
Individual window settings for all die protection inputs and PLS outputs |
![]() |
|
Individual alpha/numeric names for DP, PLS and job storage |
![]() |
|
Clutch/brake fault and prompt messages (BCD Inputs) |
![]() |
|
Remote reset push button input | ![]() |
|
Press position display (0 - 359) | ![]() |
|
Top-stop compensation when used with a Press Pilot 150 |
![]() |
|
CE compliant | ![]() |
Specifications
General | |
Die Protection | NPN, NO or NC 24 VDC |
PLS | Quantity 8 - SPDT 10A |
Brake Monitor Input |
120 VAC |
Limits | 500 SPM; Operation Temp 0-70 degrees C |
Display | 4 line x 20 Character Keypad Display |
Power | Includes 24 VDC Power Supply (2.3 Amp), requires 120 VAC (2 Amp) |
Requirements | NEMA enclosure; Encoder with cable |
Width | Height | Depth | |
Dimensions | 6 " | 4.75 " | 3.5 " |